This listing is for the J Engelsmann Jolting Volumeter STAV 11
Bjdpfx Aoxhd E Reavoww
The unit is in full working condition and is ready for immediate use
Engelsmann Jolting Volumeter STAV 11) — a compact laboratory instrument used to assess the tamped density and volumes of bulk solids before and after compaction.
The Jolting Volumeter STAV II, produced by J. Engelsmann AG, is a laboratory device engineered to measure the apparent (pre-compaction) and tapped (post-compaction) volumes of bulk materials—such as powders, granulates, and fibrous products—thus enabling calculation of tamped or tapped density
Compliance with standards: Supports analysis in line with European Pharmacopoeia, DIN ISO 787 Part 11, ISO 3953, ISO 8967, and ASTM B 527-93
Adjustable tamping mechanism: Allows custom setting of the number of jolting strokes deviating from default programs
Measurement cylinders: Compatible with a range from 10 ml to 1000 ml, with 250 ml typically standard; cylinders are interchangeable and secured via a strong retaining ring and gasket
Ease of use and cleaning: Designed with a modern, rounded “soft design” that’s easy to clean and operate via a user-friendly display and control unit
Optional accessories: Can be fitted with a sound-absorption hood for quieter operation
Bjdpfx Aoxhd E Reavoww
The unit is in full working condition and is ready for immediate use
Engelsmann Jolting Volumeter STAV 11) — a compact laboratory instrument used to assess the tamped density and volumes of bulk solids before and after compaction.
The Jolting Volumeter STAV II, produced by J. Engelsmann AG, is a laboratory device engineered to measure the apparent (pre-compaction) and tapped (post-compaction) volumes of bulk materials—such as powders, granulates, and fibrous products—thus enabling calculation of tamped or tapped density
Compliance with standards: Supports analysis in line with European Pharmacopoeia, DIN ISO 787 Part 11, ISO 3953, ISO 8967, and ASTM B 527-93
Adjustable tamping mechanism: Allows custom setting of the number of jolting strokes deviating from default programs
Measurement cylinders: Compatible with a range from 10 ml to 1000 ml, with 250 ml typically standard; cylinders are interchangeable and secured via a strong retaining ring and gasket
Ease of use and cleaning: Designed with a modern, rounded “soft design” that’s easy to clean and operate via a user-friendly display and control unit
Optional accessories: Can be fitted with a sound-absorption hood for quieter operation
Furnizor
Notă: Înregistrați-vă gratuit sau conectați-vă, pentru a accesa toate informațiile.
Înregistrat din: 2019
772 Anunțuri online
Trimite solicitare
Telefon & Fax
+44 20 38... anunțuri
Aceste anunțuri v-ar putea interesa și pe dumneavoastră.
Reușit
Mesajul dvs. a fost trimis.
Anunț mic
Duxford
1.924 km
J Engelsmann STAV 11 + capotă acustică
J EngelsmannSTAV 11
J EngelsmannSTAV 11
Anunțul dvs. a fost șters cu succes
A apărut o eroare