Unitate modulară de filtrare cu membranăGEA
Membrane Skid up to 6.25 m³/h
Unitate modulară de filtrare cu membrană
GEA
Membrane Skid up to 6.25 m³/h
Anul fabricației
2013
Condiție
Utilizat
Locație
Liestal 

Afișați imaginile
Afișează harta
Date despre utilaj
- Descrierea mașinii:
- Unitate modulară de filtrare cu membrană
- Producător:
- GEA
- Anul fabricației:
- 2013
- Condiție:
- foarte bun (second hand)
Preț și locație
- Locație:
- 4410 Liestal, Schweiz

Apelați
Detalii despre ofertă
- ID-ul listei:
- A18024946
- Ultima actualizare:
- pe 21.02.2025
Descriere
GEA Modular Membrane Filtration System up to 6.25 m³/h, in excellent condition and barely used. This equipment was used for just two validation batches, and after that has been in storage. It is currently equipped with spiral-wound nanofiltration membranes but other membrane types can be used for microfiltration (MF), ultrafiltration (UF), etc.
The complete original manufacturer documentation is included in digital format, comprising the operating manual, process flow charts, wiring diagrams, certificates, inspection reports, and other relevant technical documentation.
The system is designed to process a maximum volume of approximately 100 m³ of product (feed) per day. An average feed flow rate of approximately 4 to 6 m³/h is assumed under the “16/4” or “20/4” operating regime (Explanation: “20/4” corresponds to 20 hours of filtration operation / 4 hours of CIP cleaning).
If, at a later stage, the daily processing capacity needs to be increased or the installed membrane surface becomes insufficient due to unforeseeable fouling effects, two empty slots are provided for retrofitting additional membrane housings. The piping and recirculation pump are already prepared for such an expansion.
The membrane unit is designed for a semi-automatic cleaning-in-place (CIP) procedure. The system includes the required valves for internal circulation of cleaning solutions, followed by system flushing.
Dusdevhctwspfx Ag Ael
Specifications
- Feed volume: 400 - 500 m³/week
- Feed volume: 80 - 100 m³/day
- Feed volume: 4.0 - 6.25 m³/h
- Production time: 16 - 20 h/day
- Operating temperature: 35 to max. 65 °C
Consumption
- Power supply (pumps): 3 x 400 V, 50 Hz
- Installed power: approx. 65 kW
- Electric power consumption: 53.1 kW/h
- Compressed air: 6 bar, oil- and water-free
- Steam: 6 bar (max.)
- Seal water: approx. 75 - 150 l/h
- CIP water: approx. 19 m³/h
- CIP water per cycle: 6 m³/CIP
- Steam consumption per cycle: 100 kg/CIP
- CIP chemicals: (e.g., membrane cleaner, acid, alkali, preservative, biocide)
Limits
- Max. operating temperature: 65 °C
- Max. operating pressure: 30 bar
- pH range for feed water:
- Maximum: pH 10.0
- Minimum: pH 2.0
Cleaning-in-Place (CIP)
- Max. temperature: 85 °C
- Max. pressure: 10 bar
- pH limits (for up to 30 minutes):
- Maximum: pH 10.5
- Minimum: pH 2.0
The complete original manufacturer documentation is included in digital format, comprising the operating manual, process flow charts, wiring diagrams, certificates, inspection reports, and other relevant technical documentation.
The system is designed to process a maximum volume of approximately 100 m³ of product (feed) per day. An average feed flow rate of approximately 4 to 6 m³/h is assumed under the “16/4” or “20/4” operating regime (Explanation: “20/4” corresponds to 20 hours of filtration operation / 4 hours of CIP cleaning).
If, at a later stage, the daily processing capacity needs to be increased or the installed membrane surface becomes insufficient due to unforeseeable fouling effects, two empty slots are provided for retrofitting additional membrane housings. The piping and recirculation pump are already prepared for such an expansion.
The membrane unit is designed for a semi-automatic cleaning-in-place (CIP) procedure. The system includes the required valves for internal circulation of cleaning solutions, followed by system flushing.
Dusdevhctwspfx Ag Ael
Specifications
- Feed volume: 400 - 500 m³/week
- Feed volume: 80 - 100 m³/day
- Feed volume: 4.0 - 6.25 m³/h
- Production time: 16 - 20 h/day
- Operating temperature: 35 to max. 65 °C
Consumption
- Power supply (pumps): 3 x 400 V, 50 Hz
- Installed power: approx. 65 kW
- Electric power consumption: 53.1 kW/h
- Compressed air: 6 bar, oil- and water-free
- Steam: 6 bar (max.)
- Seal water: approx. 75 - 150 l/h
- CIP water: approx. 19 m³/h
- CIP water per cycle: 6 m³/CIP
- Steam consumption per cycle: 100 kg/CIP
- CIP chemicals: (e.g., membrane cleaner, acid, alkali, preservative, biocide)
Limits
- Max. operating temperature: 65 °C
- Max. operating pressure: 30 bar
- pH range for feed water:
- Maximum: pH 10.0
- Minimum: pH 2.0
Cleaning-in-Place (CIP)
- Max. temperature: 85 °C
- Max. pressure: 10 bar
- pH limits (for up to 30 minutes):
- Maximum: pH 10.5
- Minimum: pH 2.0
Furnizor
Notă: Înregistrați-vă gratuit sau conectați-vă, pentru a accesa toate informațiile.
Înregistrat din: 2023
Trimiteți solicitarea
Telefon & Fax
+41 61 50... anunțuri
Aceste anunțuri v-ar putea interesa și pe dumneavoastră.
Anunț mic
Borken
1.473 km
Microscop electronic de scanare (PC-SEM)
JeolJSM-6490 Bruker XFlash Detektor
JeolJSM-6490 Bruker XFlash Detektor
Anunț mic
Thisted
1.658 km
CUVA DE BRÂNZĂ TEHNOLOGIE AGRICOLĂ 12T
Landteknik12T
Landteknik12T
Anunț mic
Dortmund
1.429 km
Inducție
EFDVL-2000.1-Z
EFDVL-2000.1-Z
Anunț mic
Österreich
813 km
Doublebeltpress
KreuzmayrK2B 1250
KreuzmayrK2B 1250
Anunț mic
Bremen
1.396 km
MIXER DE OMOGENIZARE FRYMA KORUMA
FrymaVME-12/C
FrymaVME-12/C
Anunț mic
Radom
668 km
Strung
Emco Compact 10Lathe
Emco Compact 10Lathe
Anunț mic
Dortmund
1.425 km
Cuptor cu cameră de ardere cu gaz, de tip drive-through
VEIVEI-GB-KO
VEIVEI-GB-KO
Anunț mic
Germania
1.214 km
Linie de umplere cu lapte
ElopakPS 50
ElopakPS 50
Anunț mic
Thisted
1.658 km
Producția de lapte și produse lactate
APVType PCI-UF 50-100
APVType PCI-UF 50-100
Anunț mic
Velbert
1.444 km
Paletizator pentru găleți
PulspackPal-20
PulspackPal-20
Anunțul dvs. a fost șters cu succes
A apărut o eroare